Resumo do Conteúdo

Página 1 - MetroSelect

MetroSelect® Area Imaging Supplemental Configuration Guide

Página 2 - Trademarks

6 Omnidirectional and/or Linear Imager Modes The area imager can be configured to operate as an omnidirectional imager, or a linear imager, or a com

Página 3 - Table of Contents

7 Enable 1D Linear Only in Trigger Operations Disable 1D Linear Only in Trigger Operations ³120212 ³120202 Enable Linear Only in Presentation Ope

Página 4

8 Aiming and Illumination Trigger and presentation operations can be configured separately to use the imager’s linear illumination as an aiming inst

Página 5 - Imager Operation

9 * Enable Auto Gain Disable Auto Gain ³125101 ³125111 * Enable Illumination Group 1 Disable Illumination Group 1 ³124002 ³124012 * Enable Illumin

Página 6 - ³4202154

10 Data Output * Enable Data Output Disable Data Output ³121205 ³121215 * Factory default configuration.

Página 7 - ³8238100

11Character Suppression Enable the Suppression of 1 Character * Disable the Suppression of 1 Character ³115111 ³115101 To suppress 1 characte

Página 8

12 Code Bytes 0 – 9 Notes: For additional information on Code Bytes, refer to the Code Bytes Usage section of the MetroSelect Configuration Guide

Página 9 - ³8439100

13Same Symbol Timeouts Retain Same Symbol Timeout on Trigger * Reset Same Symbol Timeout on Trigger ³120013 The same-symbol timeout is not restar

Página 11

15Imager Operation – MS1633 Power Save Modes†† Enable Trigger Power-Save * Disable Trigger Power-Save ³125315 When enabled, the MS1633 will enter

Página 12 - Aiming and Illumination

Disclaimer Honeywell International Inc. (“HII”) reserves the right to make changes in specifications and other information contained in this documen

Página 13 - MS1633, and the MS1690)

16 RangeGate® Mode†† Enable RangeGate Disable RangeGate ³123707 When enabled, the MS1633 will store scanned bar codes into non-volatile memory i

Página 14 - Data Output

17Firmware Version and Address†† Transmit the Firmware Version of the Imager with Bluetooth® Wireless Technology ³998044 Transmit the Address of t

Página 15 - Character Suppression

18 Inventory Mode†† In Inventory mode, there is a quantity field associated with each bar code. When an item’s bar code is scanned, the MS1633 aut

Página 16 - Code Bytes 0 – 9

19 The quantity bar codes on page 20 enable the user to enter a quantity for the last item scanned. The item’s bar code data will be stored and tr

Página 17 - LED Options

20 Quantity Codes†† Quantity 0 Quantity 5 ³Q0 ³Q5 Quantity 1 Quantity 6 ³Q1 ³Q6 Quantity 2 Quantity 7 ³Q2 ³Q7 Quantity 3 Quantity 8 ³Q3 ³Q8 Qua

Página 18

21 Transmit Entry Counter†† * Do Not Transmit Entry Counter ³123914 Optional field transmitted with the bar code data that is a count of the numb

Página 19 - Imager Operation – MS1633

22 Enable Inventory Beep†† * Disable Inventory Beep ³123912 When enabled MS1633 will beep after transmitting each inventory record. ³123902 Delete

Página 20 - RangeGate

23Code Types and Decode Rules Data Matrix Enable Normal Color Data Matrix Decoding Enable Inverse Color Data Matrix Decoding ³200522 ³200512 Enable

Página 21 - Firmware Version and Address

24 Enable Low-Contrast Data Matrix Decoding† * Disable Low-Contrast Data Matrix Decoding ³125417 Improves decoding† of low-contrast Data Matrix

Página 22 - Inventory Mode

25 * Enable Data Matrix, Normal Size ³325402 The following bar codes improve decoding of Data Matrix symbols when the length of a symbol size i

Página 23

iiiTable of Contents Imager Operation Presentation and Trigger Modes In-Stand...

Página 24

26 QR Code Enable Normal Video QR Code Enable Inverse Video QR Code ³200612 ³200622 Enable Normal and Inverse QR Code * Disable QR Code ³200632

Página 25

27Aztec Enable Normal Video Aztec Decoding * Disable Normal Video Aztec Decoding ³100610 ³100600 Enable Inverse Video Aztec Decoding * Disable Inv

Página 26

28 Enable Aztec Structure Append Decoding * Disable Aztec Structure Append Decoding ³124416 ³124406 When this feature is enabled, Aztec bar codes w

Página 27 - Code Types and Decode Rules

29Postal Enable Australia Post * Disable Australia Post ³126217 ³126207 Enable Japan Post * Disable Japan Post ³126216 ³126206 Enable KIX Code

Página 28

30 Enable PLANET Code * Disable PLANET Code ³126214 ³126204 Enable POSTNET Code * Disable POSTNET Post ³126213 ³126203 Enable B & B’ Field

Página 29

31 Enable UPU Decoding * Disable UPU Decoding ³126211 ³126201 Enable Royal Mail 4 Code * Disable Royal Mail 4 Code ³126210 ³126200 Enable Zero

Página 30 - MaxiCode

32 Codablock Options Enable Codablock A * Disable Codablock A ³126410 ³126400 Enable Codablock F * Disable Codablock F ³126411 ³126401 PDF Opt

Página 31

33RS232 Software Handshaking Enable ]V Handshaking Disable ]V Handshaking ³125210 An “]V” response from the host indicates reception of image

Página 33

35Interfaces Additional Interfaces† Enable Beeper ON/OFF Commands * Disable Beeper ON/OFF Commands ³125211 Enables beeper on/off commands with

Página 34

iv PDF Options... 32 RS232 Software Handshaking ...

Página 35

36 IBM 46xx-SIOC RS485 Interface Send 30H for Last Block Label Identifier 4680 * Send 00 for Last Block Label Identifier 4680 ³117215 Note: Featu

Página 36 - PDF Options

37MS7580 Genesis Specific Load RS232 Configuration Settings Load USB Configuration Settings ³998071 ³998072 Load Keyboard Wedge Configuration S

Página 37 - Interface

38 Apply Settings to All Interfaces Apply Settings to the Current Interface ³998075 ³998081 Apply Settings to RS232 Interface Apply Settings

Página 38

39Enter/Exit Configuration Mode Enter Exit Configuration Mode ³999999

Página 40

41Contact Information The Americas (TA) Omniplanar, Inc. Spain USA Tel: 856.374.5550 Tel: +34 913 272 400 Tel: 800.436.3876 Fax: 856.374.557

Página 41 - MS7580 Genesis Specific

42 Chengdu Sales Office Japan Singapore Tel: 028-66135066/86786348 Tel: 81-3-3839-8511 Tel: (65) 6842-7155 Fax: 028-86787061 Fax: 81-3-3839-851

Página 43

Honeywell Scanning & Mobility 90 Coles Road Blackwood, NJ 08012-4683 00-05252 Rev B June 2009

Página 44

1Imager Operation Presentation and Trigger† Modes There are four configurable modes for scanning: the presentation mode, the multi-try trigger mode

Página 45 - Contact Information

2 Out-of-Stand‡  Presentation Mode Out-of-Stand * Multi-Try Trigger Mode Out-of-Stand ³418304 ³418324 Continuous Trigger Mode Out-of-Stand Single

Página 46

3 * Presentation Mode Immediately After Button† Release ³823800 The imager immediately reverts to presentation mode when the button is released.

Página 47

4 * Enable Trigger Press Timeout In Presentation Mode Disable Trigger Press Timeout In Presentation Mode ³124403 ³124413 * Factory default

Página 48

5Pass-Through Settings * Enable Pass-Through Scanning In Presentation Mode Disable Pass-Through Settings In Presentation Mode ³127015 ³12700